YOUYUE 858D+ hotair station — reverse engineering #6

$
0
0

Adding some more stuff is always fun.

IMGP8969

Inspired by a recent blog-post on dangerousprototypes.com, I chose to improve the fan-monitoring. The unmodified device only monitors fan voltage, which is close to useless.

With the addition of a current-sense shunt resistor (1 Ohm, very easily done), one can measure the fan-current, which is not perfect, but might be expanded to true commutation-detection (true fan-speed).

This is just the first part, simple current-monitoring. It works nicely.

IMGP8963 IMGP8965 IMGP8966 IMGP8967 IMGP8969